ENGINEERING & SAMPLING SYSTEMS
ADEV, due to provide a complete solution to solve the customer applicative problem, other than the different models of analysers, can provide complete analysis systems in accordance to customer specification, integrating the necessary automation.
ADEV projects range from simple panels or mini cabinets with just few components to big cabinets or panels that integrates multiple analysers, automation and communication.
The pictures below are a showcase of possible mounting configurations, for safe and hazardous area.
Sampling System - Example 1
Application: Monitoring of 24 burners on Copper melting furnace
Measured Gas: Hydrogen (H2)
Analyser: 8866
Technology: Thermal Conductivity
Area Classification: Safe area
Installation: Zinc Plated, self-standing Cabinet
Sampling System - Example 2
Application: Inerting control of a centrifuge
Measured Gas: Oxygen (O2)
Analyser: AtLAS-900
Technology: Laser (TDLAS)
Area Classification: ATEX Zone 1
Installation: Stainless Steel Plate for wall mounting
Sampling System - Example 3
Application: Measure of Hydrogen and trace O2 in stream of pure CO
Measured Gas: Hydrogen (H2) + Oxygen (O2)
Analyser: 8866 and EC9600
Technology: Thermal Conductivity and Electrochemical
Area Classification: ATEX Zone 1
Installation: Stainless Steel, self-standing Cabinet
Sampling System - Example 4
Application: Inerting control of a centrifuge
Measured Gas: Oxygen (O2)
Analyser: 8863
Technology: Thermoparamagnetic
Area Classification: ATEX Zone 1
Installation: Stainless Steel Cabinet for wall mounting
Sampling System - Example 5
Application: Blast Furnace (Steel Mill)
Measured Gas: Oxygen (O2) + Hydrogen (H2) + Carbon Monoxide (CO) + Carbon Dioxide (CO2)
Analysers: P8863, 8866, 8869
Technology: Paramagnetic, Thermal Conductivity, Infrared
Area Classification: Safe area
Installation: Zinc Plated, self-standing Cabinet
Sampling System - Example 6
Application: Programmable mixer for explosive mixtures with analysis and report for explosion proof tests.
Measured Gas: Oxygen (O2) + Hydrogen (H2) + Acetylene (C2H2) + Ethylene (C2H4) + Methane (CH4) + Propane (C3H6)
Analysers: P8863, 8866, 8869
Technology: Paramagnetic, Thermal Conductivity, Infrared
Area Classification: Safe area
Installation: Zinc Plated, self-standing Cabinet
Sampling System - Example 7
Application: Experimental measuring for research
Measured Gas: Carbon Monoxide (CO) + Carbon Dioxide (CO2) + Methane (CH4)
Analyser: 8869
Technology: Infrared
Area Classification: Panel: ATEX Zone 1; Control Units: Safe area
Installation: Stainless Steel Plate for wall mounting and rack 19” case
Sampling System - Example 8
Application: Monitoring of Explosive gases in ovens in Steel Plant
Measured Gas: Total Combustibles (H2-CH4-CO) calibrated as CO
Analyser: 8867
Technology: Catalytic Combustion
Area Classification: ATEX Zone 1
Installation: Stainless Steel Plate for wall mounting
Sampling System - Example 9
Application: Measure of Hydrogen in Hydrocarbons stream (Refinery)
Measured Gas: Hydrogen (H2)
Analyser: 8866
Technology: Thermal Conductivity
Area Classification: ATEX Zone 1
Installation: Stainless Steel Cabinet for wall mounting
Sampling System - Example 10
Application: Inerting control inside 4 silos
Measured Gas: Carbon Monoxide (CO) + Carbon Dioxide (CO2)
Analyser: 8863
Technology: Thermoparamagnetic
Area Classification: Safe area
Installation: Zinc Plated, self-standing Cabinet
Sampling System - Example 11
Application: Monitoring of the atmosphere inside a biological mud drier
Measured Gas: Oxygen (O2) wet and dry + Carbon Monoxide (CO)
Analyser: 8863, 8869
Technology: Thermoparamagnetic, Infrared
Area Classification: Safe area
Installation: Zinc Plated, self-standing Cabinet
Sampling System - Example 12
Application: High pressure CO2 monitoring
Measured Gas: Carbon Dioxide (CO2)
Analyser: 8869
Technology: Infrared
Area Classification: ATEX Zone 1
Installation: Stainless Steel Plate for wall mounting
Sampling System - Example 13
Application: Galvanizing furnace, scanning system on several lines
Measured Gas: Carbon Monoxide (CO) + Carbon Dioxide (CO2)
Analyser: 8869
Technology: Infrared
Area Classification: Safe area
Installation: Zinc Plated, self-standing Cabinet
Sampling System - Example 14
Application: Notified body Laboratory
Measured Gas: Oxygen (O2)
Analyser: P8863
Technology: Paramagnetic
Area Classification: Safe area
Installation: Stainless Steel Plate for wall mounting
Sampling System - Example 15
Application: Blast Furnace Pulverized Coal Injection (PCI)
Measured Gas: Hydrogen (H2) + Carbon Monoxide (CO) + Carbon Dioxide (CO2)
Analysers: 8866 + 8869
Technology: Thermal Conductivity + Infrared
Area Classification: Safe area
Installation: Zinc Plated, self-standing Cabinet
Sampling System - Example 16
Application: Hydrogen purity monitoring in Hydrogen-cooled generator
Measured Gas: Hydrogen (H2)
Analyser: 8866
Technology: Thermal Conductivity
Area Classification: ATEX Zone 1
Installation: Stainless Steel Plate for wall mounting
Sampling System - Example 17
Application: Inerting control of a centrifuge
Measured Gas: Oxygen (O2)
Analyser: 8863
Technology: Thermoparamagnetic
Area Classification: ATEX Zone 1
Installation: Stainless Steel Cabinet for wall mounting
Sampling System - Example 18
Application: Monitoring of atmosphere inside furnace for ceramics
Measured Gas: Carbon Monoxide (CO) + Methane (CH4)
Analysers: 8869
Technology: Infrared
Area Classification: Safe area
Installation: Zinc Plated, self-standing Cabinet
Sampling System - Example 19
Application: Measure of Carbon Dioxide in Natural gas
Measured Gas: Carbon Dioxide (CO2)
Analyser: 8869
Technology: Infrared
Area Classification: ATEX Zone 1
Installation: Stainless Steel Plate for wall mounting
Sampling System - Example 20
Application: Monitoring of heat treatment (Nitriding)
Measured Gas: Hydrogen (H2) + Ammonia (NH3)
Analysers: 8866 and 8869
Technology: Thermal Conductivity and Infrared
Area Classification: Safe area
Installation: Zinc Plated, self-standing Cabinet
Sampling System - Example 21
Application: Inerting control Titanium plant
Measured Gas: Oxygen (O2)
Analyser: 8863
Technology: Thermoparamagnetic
Area Classification: ATEX Zone 1
Stainless Steel Plate for wall mounting
Sampling System - Example 22
Application: Inerting control of a centrifuge
Measured Gas: Oxygen (O2)
Analysers: AtLAS-900
Technology: Laser (TDLAS)
Area Classification: ATEX Zone 1
Installation: Stainless Steel Rack